Rating Chart-B2 Type
Double Reduction Bevel Helical Gearboxes
TYPE B2-B2SF | ||||||||||||||
DOUBLE REDUCTION UNITS – RIGHT ANGLE SHAFTS – MECHANICAL AND THERMAL CAPACITIES KW | ||||||||||||||
MECHANICAL CAPACITIES (KW) | ||||||||||||||
Nominal |
Input |
Nominal |
Unit Size |
|||||||||||
140 |
160 |
180 |
200 |
225 |
250 |
280 |
315 |
355 |
400 |
450 |
500 |
|||
5.06 |
1500 |
296 |
75.9 |
114 |
150 |
224 |
322 |
450 |
618 |
830* |
1117* |
1666* |
2048* |
REFER AGNEE |
1000 |
198 |
50.6 |
75.6 |
111 |
150 |
215 |
300 |
411 |
553 |
744 |
1135 |
1542 |
||
750 |
148 |
38 |
56.7 |
84.7 |
113 |
161 |
224 |
308 |
415 |
558 |
854 |
1179 |
||
5.60 |
1500 |
268 |
72.5 |
112 |
148 |
224 |
306 |
450 |
618 |
830 |
1117* |
1614* |
2048* |
|
1000 |
179 |
50.4 |
75.4 |
108 |
150 |
215 |
300 |
411 |
553 |
744 |
1135 |
1542 |
||
750 |
134 |
38 |
56.7 |
84.3 |
113 |
161 |
224 |
308 |
415 |
558 |
854 |
1179 |
||
6.20 |
1500 |
242 |
71.6 |
107 |
143 |
224 |
288 |
450 |
618 |
830 |
1117* |
1479* |
2048* |
|
1000 |
161 |
50.3 |
75 |
105 |
150 |
215 |
300 |
411 |
553 |
744 |
1115 |
1542 |
||
750 |
121 |
38 |
56.7 |
82.6 |
113 |
161 |
224 |
308 |
415 |
558 |
854 |
1179 |
||
6.86 |
1500 |
219 |
67.4 |
100 |
137 |
212 |
277 |
415 |
618 |
830 |
1066* |
1417* |
2048* |
|
1000 |
146 |
49.4 |
73.7 |
100 |
145 |
190 |
282 |
411 |
553 |
744 |
1073 |
1542 |
||
750 |
109 |
37.9 |
56.6 |
78.3 |
111 |
143 |
215 |
308 |
415 |
558 |
834 |
1179 |
||
7.59 |
1500 |
198 |
63 |
93.6 |
125 |
181 |
252 |
378 |
502 |
713 |
965 |
1314* |
1862* |
|
1000 |
132 |
46.1 |
68.6 |
91.4 |
121 |
173 |
253 |
334 |
475 |
643 |
939 |
1313 |
||
750 |
98.8 |
36 |
53.4 |
71.3 |
90.5 |
129 |
190 |
250 |
357 |
482 |
704 |
984 |
||
8.40 |
1500 |
179 |
55.7 |
85 |
118 |
162 |
231 |
320 |
440 |
606 |
848 |
1210 |
1676 |
|
1000 |
119 |
38.4 |
58.7 |
80.8 |
108 |
157 |
213 |
293 |
404 |
566 |
821 |
1156 |
||
750 |
89.3 |
29.5 |
45.3 |
62.3 |
81.1 |
118 |
159 |
219 |
303 |
424 |
616 |
869 |
||
9.30 |
1500 |
161 |
51.2 |
76.9 |
105 |
139 |
209 |
278 |
381 |
542 |
714 |
1066 |
1490 |
|
1000 |
108 |
35.4 |
53.1 |
72.1 |
92.4 |
140 |
185 |
254 |
361 |
476 |
709 |
993 |
||
750 |
80.6 |
27.1 |
40.6 |
55 |
69.3 |
104 |
139 |
190 |
271 |
357 |
532 |
745 |
||
10.3 |
1500 |
146 |
46.8 |
69.9 |
97.2 |
117 |
169 |
228 |
326 |
434 |
647 |
897 |
1345 |
|
1000 |
97.1 |
31.3 |
46.9 |
65.3 |
83 |
120 |
163 |
227 |
320 |
431 |
652 |
899 |
||
750 |
72.8 |
23.7 |
35.4 |
49.3 |
65.9 |
93.1 |
126 |
171 |
240 |
324 |
489 |
674 |
||
For higher SIZES – refer to AGNEE. Nominal ratios are shown. Interpolate for other input speeds.* Forced lubrication is necessary. |
THERMAL CAPACITIES (KW) | |||||||||||||
Nominal |
Input |
Unit Size |
|||||||||||
140 |
160 |
180 |
200 |
225 |
250 |
280 |
315 |
355 |
400 |
450 |
500 |
||
Units Without Fan ( Horizontal) |
|||||||||||||
5.06 to 9.30 |
1500 |
40 |
52 |
64 |
79 |
99 |
122 |
153 |
201 |
292 |
373 |
425 |
Refer to AGNEE |
1000 |
41 |
52 |
64 |
80 |
100 |
124 |
177 |
241 |
328 |
454 |
584 |
||
750 |
42 |
53 |
65 |
81 |
106 |
125 |
189 |
258 |
318 |
443 |
581 |
||
10.3 to 18.9 |
1500 |
39 |
51 |
62 |
71 |
96 |
116 |
146 |
193 |
269 |
343 |
503 |
Refer to AGNEE |
1000 |
40 |
51 |
62 |
78 |
97 |
118 |
163 |
222 |
319 |
417 |
529 |
||
750 |
41 |
51 |
62 |
79 |
99 |
120 |
174 |
236 |
311 |
429 |
512 |
||
Units With Fan Cooling ( Horizontal) |
|||||||||||||
5.06 to 9.30 |
1500 |
85 |
111 |
140 |
173 |
214 |
272 |
368 |
449 |
661 |
864 |
955 |
Refer to AGNEE |
1000 |
73 |
95 |
120 |
149 |
191 |
238 |
320 |
389 |
575 |
751 |
1092 |
||
750 |
63 |
83 |
105 |
130 |
173 |
230 |
290 |
355 |
522 |
682 |
976 |
||
10.3 to 18.9 |
1500 |
84 |
109 |
137 |
171 |
212 |
275 |
331 |
389 |
548 |
701 |
860 |
Refer to AGNEE |
1000 |
71 |
92 |
117 |
146 |
189 |
233 |
285 |
353 |
470 |
612 |
871 |
||
750 |
63 |
81 |
102 |
128 |
170 |
204 |
240 |
323 |
425 |
546 |
793 |
TYPE B2-B2SF | ||||||||||||||
DOUBLE REDUCTION UNITS – RIGHT ANGLE SHAFTS – MECHANICAL AND THERMAL CAPACITIES KW | ||||||||||||||
MECHANICAL CAPACITIES (KW) | ||||||||||||||
Nominal |
Input |
Nominal |
Unit Size |
|||||||||||
140 |
160 |
180 |
200 |
225 |
250 |
280 |
315 |
355 |
400 |
450 |
500 |
|||
11.4 |
1500 |
132 |
40.1 |
64.5 |
88.6 |
108 |
155 |
209 |
300 |
401 |
577 |
827 |
1169 |
REFER AGNEE |
1000 |
87.7 |
28 |
45 |
61.9 |
71.7 |
105 |
144 |
200 |
276 |
385 |
556 |
780 |
||
750 |
65.8 |
21.1 |
33.9 |
46.8 |
53.8 |
78.8 |
108 |
150 |
207 |
289 |
418 |
586 |
||
12.6 |
1500 |
119 |
35.5 |
57.5 |
78.1 |
93.4 |
134 |
187 |
257 |
351 |
493 |
729 |
1009 |
|
1000 |
79.4 |
24.7 |
40.2 |
54.5 |
62.6 |
89.6 |
125 |
171 |
234 |
329 |
486 |
673 |
||
750 |
59.5 |
18.5 |
29.9 |
40.5 |
47 |
67.2 |
93.5 |
128 |
176 |
246 |
364 |
505 |
||
14.0 |
1500 |
107 |
30.9 |
46.7 |
65.2 |
80.7 |
115 |
158 |
217 |
305 |
446 |
656 |
933 |
|
1000 |
71.4 |
21.6 |
32.6 |
45.5 |
57.6 |
82.1 |
114 |
115 |
219 |
319 |
468 |
66 |
||
750 |
53.6 |
16.2 |
24.3 |
33.8 |
38 |
64.3 |
88.9 |
122 |
171 |
246 |
364 |
504 |
||
15.4 |
1500 |
97.4 |
28.6 |
42.9 |
57.2 |
74.3 |
106 |
146 |
207 |
298 |
411 |
604 |
860 |
|
1000 |
64.9 |
20 |
30 |
40 |
52.3 |
75.5 |
104 |
143 |
200 |
283 |
413 |
573 |
||
750 |
48.7 |
14.8 |
22.3 |
29.8 |
39.2 |
58.4 |
80.7 |
109 |
150 |
212 |
309 |
430 |
||
17.1 |
1500 |
87.8 |
24 |
37.9 |
52 |
62.4 |
96.4 |
119 |
178 |
242 |
323 |
462 |
663 |
|
1000 |
58.5 |
16.8 |
26.5 |
36.2 |
41.6 |
64.3 |
79.2 |
119 |
161 |
215 |
308 |
443 |
||
750 |
43.9 |
12.5 |
19.7 |
27 |
31.1 |
48.2 |
59.4 |
88.8 |
121 |
160 |
232 |
332 |
||
18.9 |
1500 |
79.4 |
23.4 |
35.2 |
48.6 |
62.4 |
87.5 |
119 |
170 |
242 |
316 |
462 |
663 |
|
1000 |
52.9 |
16.4 |
24.5 |
33.9 |
41.6 |
58.3 |
116 |
116 |
161 |
210 |
308 |
443 |
||
750 |
39.7 |
12.2 |
18.2 |
25.2 |
31.1 |
43.8 |
86.5 |
86.5 |
121 |
157 |
232 |
332 |
||
For higher SIZES – refer to AGNEE. Nominal ratios are shown. Interpolate for other input speeds.* Forced lubrication is necessary. |
THERMAL CAPACITIES (KW) | |||||||||||||
Nominal |
Input |
Unit Size |
|||||||||||
140 |
160 |
180 |
200 |
225 |
250 |
280 |
315 |
355 |
400 |
450 |
500 |
||
Units with cooling coils* ( Horizontal) |
|||||||||||||
5.06 to 9.30 |
1500 |
106 |
135 |
152 |
169 |
242 |
588 |
679 |
1420 |
1590 |
2330 |
1960 |
Refer to AGNEE |
1000 |
106 |
135 |
151 |
169 |
238 |
533 |
611 |
1270 |
1440 |
2170 |
1860 |
||
750 |
105 |
134 |
151 |
169 |
235 |
507 |
571 |
1180 |
1340 |
2020 |
1740 |
||
10.3 to 18.9 |
1500 |
101 |
129 |
145 |
161 |
238 |
437 |
471 |
990 |
1110 |
1680 |
1450 |
Refer to AGNEE |
1000 |
100 |
128 |
145 |
161 |
235 |
423 |
449 |
896 |
998 |
1510 |
1310 |
||
750 |
100 |
127 |
144 |
160 |
233 |
414 |
440 |
849 |
629 |
1400 |
1210 |
||
Units With Fan Cooling and cooling coils *( Horizontal) |
|||||||||||||
5.06 to 9.30 |
1500 |
161 |
206 |
231 |
257 |
317 |
755 |
899 |
1720 |
1980 |
2820 |
2540 |
Refer to AGNEE |
1000 |
148 |
189 |
213 |
236 |
286 |
636 |
751 |
1470 |
1700 |
2500 |
2240 |
||
750 |
138 |
176 |
198 |
221 |
260 |
580 |
670 |
1320 |
1520 |
2270 |
2030 |
||
10.3 to 18.9 |
1500 |
141 |
180 |
202 |
224 |
288 |
545 |
608 |
1190 |
1380 |
2040 |
1890 |
Refer to AGNEE |
1000 |
133 |
169 |
190 |
211 |
263 |
495 |
537 |
1020 |
1160 |
1740 |
1580 |
||
750 |
124 |
159 |
115 |
199 |
242 |
468 |
505 |
940 |
1050 |
1550 |
1400 |
||
Full load efficiency -97%, 8 Based on cooling water temperature 20o C |